Lipid nanoparticle formulations frequently fail when they move from the laboratory to manufacturing scale, because the mixing conditions that determine particle size, polydispersity and encapsulation efficiency change with equipment geometry. This article looks at the critical quality attributes that matter for LNPs and liposomes, the formulation methods used to make them, why scale-up so often breaks a working formulation, and how membrane-based crossflow mixing keeps the mixing mechanism constant from discovery through to GMP production.
As we seem to have ‘moved on’ from COVID-19, relegating it to the “I’d rather not go back there” bin, we have a problem, the tiny little virus and its friends haven’t. Thankfully a few of us have this front of mind, continuing to push for sovereign capacity to develop and manufacture nanoparticle therapeutics in Australia and New Zealand, knowing we can only depend on ourselves given global uncertainties. Fortunately, the world benefitted from a unique unity of global scientists on a common quest to defeat a common scourge. The challenge then was not only the vaccine, but how to scale it for billions. It was achieved but with a clunky, problematic method that persists today despite a clear path to efficient scalable GMP production. If vaccines are not your interest, you may be motivated if the same technique can accommodate therapeutics for cancer, genetic disorders, and infectious diseases, for humans, wildlife, and animals such as sheep and cattle.
What are the critical quality attributes for nanoparticle drug products?
For lipid nanoparticles the core critical quality attributes are particle size, polydispersity index, surface charge and encapsulation efficiency, with further attributes added depending on the active ingredient and route of administration. The International Council for Harmonisation (ICH) of Technical Requirements for Pharmaceuticals for Human Use publishes guidelines for Critical Quality Attributes (CQAs) of a drug substance. “A CQA is a physical, chemical, biological, or microbiological property or characteristic that should be within an appropriate limit, range, or distribution to ensure the desired product quality. CQAs are generally associated with the drug substance, excipients, intermediates (in-process materials) and drug product” [1] The Australian Therapeutic Goods [2] Administration seems to directly cite the ICH guidelines.
With respect to Lipid NanoParticles and their payload, there are several core CQAs including: Size, Polydispersity Index (PDI), Surface Charge (zeta potential), Encapsulation Efficiency (EE) and depending on the Active Pharmaceutical Ingredient (API) there are specific quality attributes, additionally these vary depending on route of administration [3] and tissue targeted. As the numbers of drug products expand, so too will the CQA’s as the knowledge base develops.
Particle size is critical as noted by [3], this varies greatly depending on the tissue tropism, for example 40 nm maybe ideal for an inhalable targeting the lung, whereas 60 to 100 nm works best for an intramuscular injection for an immune response. The PDI is a measure of the span of particle sizes, for example if the PDI is low (<0.2) then the particles are virtually homogenous, a favourable condition particularly if you require a very specific size. LNP half-life is an important consideration, and it appears to be strongly influenced by its very composition. Approx 90% of the dose or LNP mRNA formulations with the Onpattro lipid composition is cleared to the liver within 30 min of i.v. administration [4], circulation times can increase with addition of PEG coating, however this can impact the cellular uptake. Interestingly [4] found that egg sphingomyelin as a replacement for the helper lipid, DSPC (1,2-distearoyl-sn-glycero-3-phosphorylcholine) up to 40 mol% can exhibit comparable or superior levels of protein expression [4].
Encapsulation efficiency (EE) is simply how much of the active ingredient is loaded within the nanoparticles. The determination of this varies contingent on the cargo; for mRNA it is common to use a Ribogreen Assay [5] that consists of a fluorescent dye that binds to the mRNA, quantification of the total solution is recorded (A), then the solution is exposed to a surfactant that disrupts the nanoparticle, releasing the mRNA, the fluorescence(B), is again measured. A simple subtraction of B-A yields the EE. Beyond 85% is broadly judged positively. Questions have been raised on the accuracy of this assay which generally centre around the starting RNA concentration and the yield. This will be discussed a little later.
Further discussions include the distribution of the payload within the nanoparticle plus the individual load capacity of each particle and the percentage of “empties”. There are also differences as [6] found subject to the payload size. Clearly quite nuanced.
Zeta potential, which is a measure of the electrostatic or charges repulsion / attraction between particles and is a predictor of emulsion and dispersion stability. Zeta potential is a function of both the particle surface and the dispersant. It provides information that is critical to formulators during the design of multi-component products [7], [48]. Zeta potential characterises the electrical double layer and the nanoparticle, the colloidal formulation itself. It gives information about the stability, circulation time, protein interactions, permeability, and biocompatibility of the nanoparticles [8] For the underlying method, see our electrophoretic light scattering measurement principle page.
The importance of Quality by Design (QbD) and CQAs in therapeutics is paramount to ensure a product is not affected by scaled manufacture where the resultant could be clinically catastrophic. A research lab making small volumes of an LNP must be cognisant of not all formulation platforms can be truly scaled. A good example of this is microfluidics where scaling requires altered flow and possibly variations to the formulation, [9] researched the work where Enot describes the necessity to match the Reynolds numbers and Dean numbers of one system to another ensuring formulations are similar. Additionally, as she moved a formulation from the low volume system to the next volume device there was a significant increase in mechanical loss of the pDNA payload. Advanced Cross flow is not affected by CQA drift as it is scaled. Hussain and Perrie noted “These results confirm the ability to scale from the AXF-mini through to the large-scale AXF-one without changing process parameters” [10].
Cross platform formulations were assessed by Manjari Lal of PATH, Seattle [11]. The significance of this study is evidence that there is no basis to assertions you cannot transfer a formulation from one technology to another. It is clear if the formulation recipe works, it can be transferred. The Micropore’s AXF technology can produce formulations for discovery, tech transfer and GMP quantities without need of equipment or technology change to achieve scaling.
Why is particle size distribution more than a number?
Because two formulations can share a mean size and behave completely differently, the spread of sizes around that mean determines efficacy as much as the mean itself. Any given formulation will have a target particle size to achieve the desired efficacy. Beyond size, the polydispersity index (PDI) is fundamental. What is the PDI? It is a term that has multiple meanings. In the light scattering area, the term polydispersity is derived from the polydispersity index, a parameter calculated from a Cumulants analysis of the DLS measured intensity autocorrelation function [12], [47]. A clearer explanation seems to be: For a theoretical Gaussian distribution, the overall polydispersity is the distribution’s relative polydispersity. By tradition, this overall polydispersity is called the polydispersity index (PDI), the square of polydispersity by light scattering. In a perfectly uniform sample, the PDI is 0.0. This jargon translates to a measure of the degree of size variation. Imagine a mean size is 80 nm but there is a spread of smaller and larger sizes. PDI defines how much spread there is. If a monodispersed sample is assessed the PDI would be 0.0, In the realm of LNPs, a 0.2 PDI is broadly acceptable. See our dynamic light scattering measurement principle page for the technique behind this calculation.
The route of delivery somewhat defines the particle size requirement. Danaei’s paper [13] describes optimal sizes for systemic delivery avoiding losing the nanoparticle via renal clearance, gaining resident time in circulation, and the variation needed to target tumours, or administration to the lungs, brain, and liver. How this changes for transdermal transport. It is clear ‘one size does not fit all’, and nanoparticles used for drug deliver is a nuanced specialty. If your application requires aerosol delivery, this is a completely different can of worms to open. Thankfully Traini et al of the Woolcock Institute [14] have decades of research expertise of dispensation to the lungs citing optimal sizes, charge, hydrophilicity, lipophilicity and the effect of deviations from the ideal state. The paper defines just how different the nanoparticle needs to be if you are choosing orally or intranasally inhaled. Then the purpose of the administration will dictate the nanoparticle composition and attributes, for example ‘surface charge is a critical parameter influencing the efficacy of particles and droplets designed for brain delivery via the lung or intranasal routes. The surface charge, typically quantified as zeta potential, affects particle stability, mucosal adhesion, cellular uptake and transport across biological barriers [14]. Crossing the Blood Brain Barrier (BBB) has been a common aspiration for many years. The Trigeminal pathway reveals a promising route given once absorbed by the nasal mucosa drugs travel along the trigeminal axons to the pons giving them access to the Cerebral Spinal Fluid (CSF) by diffusion and ultimately targeting the Central Nervous System (CNS). Additionally, there are a couple similar conduits such as the Olfactory pathway, where an intranasally inhaled drug first passes through the nasal cavity before reaching the respiratory mucosa, located in the uppermost region of the nasal cavity, where the olfactory pathway begins, plus a peripheral pathway where both intranasally and orally inhaled therapies can influence the CNS by achieving sufficiently high systemic circulation [14].
Delivery of nanoparticles (NP) to solid tumours has long relied on enhanced permeability and retention (EPR) effect, involving permeation of NPs through a leaky vasculature with prolonged retention by reduced lymphatic drainage in tumour [15]. Despite significant progress to enhance the EPR effect there are many challenges remaining. The Tumour Microenvironment (TME) in solid tumours exhibit vast heterogeneity in their cellular composition, extracellular matrix, blood vessel architecture, and metabolic activity [16]. Additionally, the EPR varies from tumour to tumour and species to species increasing the degree of complication researching the best strategy. For example, whilst research may work well in a mouse model, it may fail in human. Gaining in-depth knowledge of the TME using advanced imaging, molecular assays, and biomarker analysis may enlighten a synergistic path for enhanced nanoparticle delivery targeting highly specific components of the TME affording a suitable result. [16] offers that a combination of strategies using such things as checkpoint inhibitors, immunotherapies and NP targeting in concert to improve the outcome. Adding, “by deepening our understanding of the TME and integrating EPR-enhancing strategies with complementary therapeutic approaches, we can move closer to developing more effective and personalized cancer therapies.”
“A major bottleneck in the field is the release of mRNA-LNPs from the endosomal pathways into the cytosol of cells where they can execute their encoded functions. The data regarding the mechanism of these endosomal escape processes are limited and contradicting” [17]. The emerging field of Endosomal escape has vast volumes of information, that is excessive for this review, beyond what follows it is worth studying [17] given the depth of information it affords. The complexity of the endosomal system begins with early endosomes, the first compartment that an LNP encounters once endocytosed. The compartment is slightly acidic due to an enzyme proton pump and numerous proteins to promote fusion and tethering. Many LNPs are recycled back, whilst others are trafficked to the late endosome where some feel this is where lysosomes end them. Some research notes the addition of Ca2+ and Zn2+ to the nanocarrier causes a change in osmotic pressure in the lysosome altering the balance and ultimately releasing the drug into the cytosol. Nuanced! “In addition to LNPs, it is interesting to explore other lipid-based platforms that do not rely on endocytosis mechanisms for cargo delivery. For example, many viruses and bacteria bypass receptor-mediated endocytosis and endosomal trafficking by direct fusion with the plasma membrane and deliver the nucleic acid directly into the cytoplasm of the host cell In a similar fashion, some lipid molecules enable liposomes to fuse with the cell membrane directly. This leads to efficient and faster delivery of the payload” [17] Relating this to optimal particle size is equally important given one size may be optimal to be endocytosed, there is growing interest in designing particles that swell as a response to the drop in pH, Angus P. R. Johnston of Monash University [18] authored an interesting review showing enhanced gene silencing using a nanogel compared to micelles despite similarities where the nanogel swelled from 80 nm to approximately 130 nm suggesting it isn’t just size that matters, so does the swell, and composition plus a myriad of other mechanisms.
How are nanoparticles actually made?
Nanoparticles are made either by breaking larger material down under high energy, or by letting chemistry assemble them from solution, and the second approach has proved far better suited to fragile nucleic acid cargo. The method of creation for nanoparticles is as varied as the chemistry used. Consider the top-down approach where the ingredients are mixed together in a vessel whose contents are passed through a device like a homogeniser that flows it through a small orifice under a deal of pressure a multitude of times to bring the size down to the desired level. This has a few major disadvantages notably heat generation and high shear. The bottom-up approach has proven to be more successful with clever chemistry that self assembles upon mixing, Nanoprecipitation. ‘During particle formation, the ionizable lipids become positively charged, and, through electrostatic interactions with the negatively charged phosphate backbone of nucleic acid polymers, promote nucleic acid incorporation into the emerging nanoparticle [19].’ Sounds simple and with a recipe it is; the development was lengthy and hugely challenging; it was quite the race to create a winning lipid that would ultimately ‘serve two key functions including facilitating nucleic acid encapsulation in LNPs and mediating endosomal membrane disruption to enable nucleic acid release to the cytosol. Further, the ionisable lipids may also play an important role in endosomal uptake, either directly through interaction between the positive charge on some ionisable lipids and the negatively charged cell membranes or via their binding to plasma proteins that support cellular uptake [19].’
Superior mixing needs to follow a simple tenant, mixing rate must be faster than assembly rate (ie microseconds). Some also argue the mixing should be in laminar flow, however in practice this need not be the case [20]. A virtual explosion of technologies followed the discovery of lipid nanoparticle creation and their capacity to encapsulate a payload. At the forefront of this charge was the microfluidic mixers such as staggered herringbone, T-Mixers, Impinging Jet, and Dean Vortex bifurcating [21] to name a few. During the COVID pandemic, a small company in the UK thought they may be able to help the global push for a vaccine. They made systems to produce microemulsions but figured they could translate this to nanoparticles. It was Yvonne Perrie of Strathclyde University who tried it and commented that it not only works, but it does so particularly well. The challenge for Micropore Technologies was they knew how to do huge volumes; they must miniaturise it. This is distinctly different from most other technologies, who start in small scale then attempt to progress to larger volumes. This is a terrific attribute of the Micropore Technologies AXF system, it is so, so easy to scale. This is evidenced by the CPI report “Evaluation of AXF Pathfinder and Horizon Mini™ for Poly(A) and mRNA Lipid Nanoparticle Production” [22]
Microfluidic Mixing
The devices that fall under the heading ‘microfluidic mixers’ is a very broad array of approaches to some core fundamental attributes. An aqueous stream is mixed with a solvent stream, for LNPs this is buffer (containing payload, eg RNA) as the aqueous and a concoction of lipids and other components are dissolved in the solvent, commonly ethanol. The recipe for these phases depends heavily on the payload, it’s charge and how it interacts with counter charges and a multitude of factors. You can make self-assembled particles by bucket chemistry, that is tip the two phases into a bucket and they will form particles, pretty poor ones, but particles, nonetheless. What microfluidic mixers bring to the party is a way to efficiently mix the two phases rapidly and in such a way all parts of each phase interact with the other phase, again, mixing rate must be faster than assembly rate, not as easy as it sounds. T-Mixers tend to create a head on collision of the phases forcing them together at high speed. This simply works.
Impinging Jet mixers are similar to T-Mixers in as much as they collide streams together. ‘Confined Impinging Jet Mixer (CIJM) has two impinging jets with equal momenta. The liquid solutions, typically a solvent and a non-solvent, are injected into the CIJM and deflect off each other, creating extreme turbulence and rapid mixing. Nanoprecipitation occurs in an order of milliseconds; thus, mixing must occur within this short window of time. Due to the speed and chaotic nature of this mixing processes, it is difficult to make predictions without a posteriori knowledge.’ [23]. It is clear they work as shown by PATH in Seattle [11].
Staggered Herringbone mixers are far gentler, bringing together the phases through a microfluidic channel which has protruding features designed to tumble the phases, so they mix completely. What was seen as a step up from this was the Dean Vortex Bifurcating Toroidal mixer that, similar to the staggered herringbone mixer, it gently brings the phases together into a series of offset circular channels that tumbles and heightens the flow ferocity by the use of centrifugal forces. They claim to be in laminar flow and whilst it maintains a Reynolds Number less than 1, by definition they are. What are the claimed benefits for laminar flow vs turbulent flow? It has been suggested, laminar flow by nature is repeatable given the fact a pure laminar flow is completely reversible. If physics is not your thing, then a cool example shown by the University of New Mexico can be found here.
Where the rubber hits the road is the challenge to scale up. Consider what was mentioned earlier, Micropore Technologies AXF method could make massive volumes, they had to miniaturise it. All the Microfluidic mixers have a similar predicament, they do small lab scale well; however, they have some constraints in scaling up. Oh, and if they state they can, ask, is this really scaling out (therefore you need to buy multiple systems)? By example, consider a T-Mixer, simple by design, turbulent flow, the rate of mixing relies on the flow rates of the two phases. If you need to push at a Total Flow Rate (TFR) of, say 470 ml/min through a T mixer (to achieve your target size) which has channels that are about 5 µm in diameter there is a volume limit to flow. If you attempt to solve this by increasing the diameter then naturally you need to increase the speed to compensate, the size of the pumps become unrealistically huge, notwithstanding the other attributes such as pressure and shear. With microfluidics is it is a terrific challenge to attempt to scale it up for volume production. Vendors do not always make this constraint clear. A formulation may need to change to survive scale-up, and headline scale volumes often assume multiple systems running in parallel, which is scaling out rather than scaling up.
Membrane-Based Crossflow Mixing
Given what we understand about nanoprecipitation, and the influx of ‘me too’ and blatant copies of existing technologies to hop on a band wagon chasing money, there was a clear need for something like a paradigm shift that would allow small scale production of nanoparticles, and importantly, solve the scaling up conundrum.
Instead of running two streams into each other through a tiny channel to ensure complete mixing, the team at Micropore Technologies used a method called Advanced Cross Flow (AXF) where, if you imagine a pipe with holes laser drilled into it, this is inside another pipe. Through the centre flows a continuous phase, often the aqueous phase with the payload and entering the flow through the thousands of tiny holes is the dispersed phase, in LNPs this would be the ETOH / lipid mix.

‘This entire mechanism depends on the interaction between crossflow conditions and phase exchange at the membrane interface, in contrast to microfluidics, which is only determined by channel geometry. This distinction is significant as it provides an alternative method for controlled particle creation while establishing a platform that is intrinsically more conducive to reuse and scalability.’ [22]
Further to this, when microfluidics need to scale it is a definite risk that the formulation that has been developed, sometimes over years, suddenly needs to be changed to compensate for dramatic fluid path variations in size (not really easy to scale). Independently, the Centre for Process Innovation (CPI) noted ‘the study represents a notable advance by diminishing the necessity for extensive re-characterization generally mandated when transitioning between various small and large-scale mixing systems’. [22]
Another discrepancy is many in the industry claim if you start on one technology, you cannot switch to another. This is a bit of a stretch really, considering, with the AXF technology, in head-to-head trials with the same lipid mix and buffer, it not only made nanoparticles, it prevailed with better EE’s and higher recovery percentages [22]. Another little-known fact is if you have a challenging formulation that due to the formulation having issues in scaling up to withstand the higher flow conditions, you need not re-formulate, the AXF mixer membrane can be altered to accommodate it. This highlights the shear flexibility of this technology.
One can postulate why even at scale the Micropore AXF system can have EE’s of near on 100% and recovery % around the same where others struggle [22]. The system operates at very low pressure and low shear. This gentle approach is likely one reason, the advanced crossflow method mixes the phases extremely efficiently; two streams are joined in a state of continuous flow as opposed to smashing them together or relying on features within a cartridge to create the mixing vortices.
The Micropore Pathfinder™ (volumes formulated 0.2 to 250 ml) and Horizon™ (from a few mls to thousands of litres GMP) systems are free from consumable mixing cartridges or massive GMP Fluid path changes (and their astronomical prices). The Mixer is entirely 316 Stainless Steel (SS), it will last for years.
The debate over single use technologies (SUT) seems to be at a tipping point, validation and standards imposed by regulators are concerning many in Pharma. In a recent article, it was argued ‘imagine you cannot get one of the plastic bits anymore, the company deletes it, the plane fell out of the sky, the boat sunk on the way, I think you would be wishing you chose good old 316SS.’ [26] Not such a silly statement, do you remember how hard it was to get anything during COVID lockdowns? The same article cites the estimated costs to attempt a new extractables study which is fuelling the reluctance to switch from one SUT to another. See our full article on single use in bioprocessing and GMP environments.
Visualising just how the Micropore AXF can scale is easier when you see Figure 2. The smallest SS mixer is the ‘Mini’, it is used in the Pathfinder systems and the Horizon ‘Mini’ where it can formulate up to 20 litres per hour, exemplifying the absolute power to scale, the identical mixer! The AXF-1 is around 10 x longer than the Mini, and this equates to a virtually linear relationship where it produces 10 x more volume than the Mini (ie 200 L / hr). If you need to produce even more volume the AXF-N is customisable to your need, the one shown arguably will produce up to 1400 L/ hour, maintaining the same mixing architecture [49].
It is worth noting the extra power this technology wields, the system supports formulation of LNPs, liposomes, polymer nanoparticles, and microspheres, with 21 CFR Part 11 compliance available on GMP models. When it comes to changing the scale up paradigm, the AXF technology is a no brainer! Further information can be found on our nanoparticle formulation applications page.
Extrusion
‘Liposome extrusion is a widely used process in which liposomes are forced under pressure through filters with defined pore sizes to generate a homogeneous population of smaller vesicles with a mean diameter that reflects that of the filter pore.’ [28] The simplest is like that of the Avestin Liposofast pictured in Figure 4. It is a basic method, ideal for small volume, low-cost nanoparticle generation. Larger volumes, up to 50 ml can be attained using a larger model, the LF-50 which employs air pressure (up to 600 psi) to an enclosed vessel forcing the sample through the porous membrane. Whilst effective, large scale approaches have been hampered by pore clogging resulting in poor outcomes.
High Pressure Homogenisation
This method is well established and has found some definite niches where it persists. Common uses have included cell lysis, emulsion chemistries, size reduction, and mixing. It works by passing a liquid through a small orifice under extremely high pressure (100 to 2000 bar) [29]. ‘The liquid obtains high velocity (more than 1000 km/h) by enforcing high pressure, resulting in a break down the accelerated particles to submicron size, caused by generated shear stress and cavitation forces’ [29]. The process is repeated time and time again through a recycle loop until the target size is achieved. As you may surmise, this ultimately raises temperatures. When temperature control is necessary, many devices are plumbed in with a cooling system such as a chilled waterbath. The technology can be ideal for some emulsions where temperature and shear have little bearing on the outcome, the Emulsiflex-C500 & Emulsiflex-C1000 Homogenisers are capable of producing large quantities of emulsions up to 1000 L/h [30]. For LNPs it is unlikely that High pressure homogenisation would be suitable, especially with fragile cargos. Given the maturity of the technique, it should be noted that more contemporary ‘inventions’ are referenced to it. See our high pressure homogenisation measurement principle page.
Why does scale-up fail, and how do you prevent it?
Scale-up fails when the mixing environment changes with equipment size, because the self-assembly that sets particle size, PDI and encapsulation efficiency is exquisitely sensitive to local conditions. ‘”This is where formulations come to die!” These are words of a prominent pharmaceutical company GMP formulations lead. What makes this so difficult? How can a formulation go this far before falling over? Presumably there have been extensive clinical trials, yet as soon as scaling is called for something fails.’ [20]
Current lipid nanoparticles are not a simple mix of components and it’s done; there are hugely complex interactions that contribute to the self-assembly process. Variability is scrutinised with the imposition of tight Critical Quality Attributes (CQAs) by regulators for good reason. It can be demonstrated that small variations in mixing, temperature, even concentration substantially affect stability, particle size, PDI, and EE. With this in mind, think of the control in scaling massive collisions with turbulent mixing, huge shear and with shear comes heat, perhaps cooking your RNA, not to mention the harsh treatment on a fragile molecule. Schrober et al [31] noted “encapsulation efficiency (EE%), as traditionally calculated, describes the percentage of RNA in the sample that is encapsulated by LNPs. However, this ratiometric calculation does not take into consideration the amount of RNA used for the LNP synthesis, and what percentage of that input RNA is encapsulated in the final product. There are several reasons the input RNA concentration should be considered in the evaluation of encapsulation efficiency. Total RNA concentration measured in the sample, post synthesis, is not likely to match the input RNA concentration. RNA, especially shorter strands lacking secondary structure, are delicate and highly susceptible to degradation by enzymes that break down RNA into smaller pieces named Ribonucleases (RNases). Processing steps after LNP formulation (i.e. buffer exchange, centrifugal concentration steps, etc.) may cause preferential degradation of unencapsulated (unprotected) RNA in the sample due to unintentional RNase contamination. In addition, the synthetic procedure uses microfluidic mixing where rapid flow rates produce shear stress, which may cause mechanical degradation of RNA. This will also decrease the amount of RNA in the sample. These degradation mechanisms will artificially increase encapsulation efficiency by decreasing the unencapsulated RNA concentration.” This is quite important, the amount of pressure in a microfluidic channel can be 60 bar, and impinging jet mixers are well beyond this.
Whilst addressing this it may be useful to describe when attempting larger scale, “one constraint associated with IJMs is the significant pressure drop incurred when pumping high volumetric flow rates through the mm-sized nozzles, potentially leading to substantial pumping costs. In addition, there are some potential operational limitations when using IJMs. The iso-momentum/iso-kinetic requirement. Moreover, maintaining the oscillatory dynamic behaviour in CIJs required to achieve the best mixing performance can be challenging due to their sensitivity (e.g., impingement instability) and inherent randomness at high Reynolds numbers. For example, dynamic oscillations may induce pressure fluctuations, resulting in oscillatory pumping behaviour which disrupts the process. Coupled with the complexity of in situ analysis and control of the mixing behaviour, these operational challenges may prevent IJMs’ usage [32].
Interesting how these limitations of process are conveniently overlooked in the quest for expediency. More concerning is how organisations tend to follow each other like sheep feeling it is tried and tested, so it’s a good choice; right? Food for thought! I often wonder how such issues meet the ICH (International Council for Harmonisation) design space guideline. ‘Design Space The relationship between the process inputs (material attributes and process parameters) and the critical quality attributes can be described in the design space.’ [33]
‘A design space can be described in terms of ranges of material attributes and process parameters, or through more complex mathematical relationships. It is possible to describe a design space as a time dependent function (e.g., temperature and pressure cycle of a lyophilisation cycle), or as a combination of variables such as components of a multivariate model. Scaling factors can also be included if the design space is intended to span multiple operational scales. Analysis of historical data can contribute to the establishment of a design space. Regardless of how a design space is developed, it is expected that operation within the design space will result in a product meeting the defined quality. [33]‘
What are the CQA’s for LNP and RNA-based therapeutics? How do they look across the critical scales of the formulation and production? At present the TGA have noted in their Messenger RNA (mRNA) technology position statement [34]: ‘At this stage the TGA feels that adopting a platform approach is premature given the mRNA technology is relatively new. There is currently insufficient regulatory experience with mRNA products to know what elements of a regulatory dossier can be applied between different products, and what specific components of a product are of potential significance for its efficacy and safety.’ Suffice to say they will be taking a case-by-case approach. The FDA seem to have a mash up of human gene therapy, liposome guidelines (FDA Liposome Drug Products Guidance) and ICH guidelines [35].
Keith Peden of the FDA Laboratory of DNA Products “Public Workshop on FDA Guidance to Industry on Nanomaterial October 11, 2022, [36]” presented ‘Considerations for the Quality, Safety and Efficacy of Prophylactic Lipid Nanoparticle mRNA Vaccines’ reported a great deal of questions and CMC issues around mRNA drug substances. In context this seemed to be a public discourse after the height of the COVID-19 pandemic. In many ways is could be construed as a guidance on what concerns the FDA given the apparent lack of any specific definitive guide. If you are keen to understand the current FDA thoughts around prior knowledge there is a draft guidance from June 2026.
A platform analytical method is a multi-product method suitable to test quality attributes of different products without significant change to its operational conditions, system suitability and reporting structure. This type of method would apply to molecules that are sufficiently alike with respect to the attributes that the platform method is intended to measure [37]. An in-depth perspective from a past head of the TGA can be found in “The Platform Technology Approach to mRNA Product Development and Regulation” [38].
Broadly speaking, most metrics associated with LNP-RNA formulations include the following: Particle Size, Polydispersity Index, Encapsulation Efficiency, and RNA Concentration, tracking these are primary indicators of scalability. At small scale most devices are very capable of creating nanoparticles efficiently, they fall over when they go to scale. Geometric similarity is one factor, but a judicious look is advised. Just because they look the same, perhaps the key attributes of the mixing are different. Think of creating an IJM at scale to replicate linearly the same flow conditions on what is a random mix. Even microfluidics fails to scale greatly as the knock-on effects of making ever larger channels is how the Reynolds number and in some cases the Dean numbers align with the small scale, additionally, whether you can find a pump suitable to flow accurately at the higher rates. The size of the pump tends to be a hinderance. AXF seems to scale linearly from the Mini with its membrane being 10-fold smaller than the AXF-1, this translates to the mini capacity of 20 Litres per hour and the AXF-1 is 200 Litres per hour [49]. Immunity to less robust formulations isn’t assured to any mixer. AXF technology has the potential to alter the membrane to suit the failing formulation, dispensing with the need to go back to the drawing board and re-formulate. See also our article on 5 recurring challenges when scaling up formulations.
Australian Genetic Medicine Manufacturing Ecosystem
ATA Scientific have been a proud voice in promoting the need for a Genetic Medicine Manufacturing Ecosystem. Back in March 2021 we published the first of a series of articles building consciousness of the need.
‘Australia has a proud history of world-class research, at times translating these findings into amazing medicines. We stand tall, wave the flag and laud such forays in global recognition and impact, citing how the latest eureka moment adds to notable achievements of years past from a relatively tiny nation punching above its weight with brilliant Nobel Laureates. Scientific endeavour requires talent, patience, time and funding, a whole lot of funding. Importantly science of the future needs to coordinate a skill-mix of brilliant minds from many disciplines coming together to develop solutions to the questions posed. The scientific tradition of sharing talent to the far corners of the planet may work in our favour in the current pandemic, however attracting such people is easier when the environment is conducive to them. Indeed, Australia has amazing scientists, respected worldwide. We do have some cool infrastructure, but do we have an ecosystem?’ [39] Given this excerpt is from 2021, you may feel that not much has changed, but after years of lobbying there has been patent steps to a solid ecosystem. The series continues in part two and part three.
The pandemic taught us just how exposed we were to reliance on others rather than ourselves, at times we cannot rely on our friends. There was a national planning event I witnessed, the round table, with the Australian Academy of Science. This was a major catalyst for funding, initially the group we colloquially called the ‘RNA Mafia’ (Australian & New Zealand RNA production Consortium (ANZRPC)) were collegiate, almost ambivalent, to where in Australia a facility would be located, as long as we got one. As time and resources were directed, where we are today is extraordinary with CSL expansion, Moderna facility, BioNTech, Monash MIPS, UNSW RNA Institute, Doherty /AIID, RNA VIC, AIBN / BASE RNA UQ, UWA, Griffith Uni, NSW Government with Aurora Biosynthetics, CSIRO Manufacturing, plus a wealth of private organisations building out capacity. See also the importance of RNA research in Australia, the Australian RNA Production Consortium, and the UNSW RNA Institute’s work using the Micropore Pathfinder.
As with any disruptive industry, there are those that wish to dictate how it is structured, opportunists and entrepreneurs identifying a niche to exploit, winners and losers, culminating in a sustainably resilient ecosystem that has matured from a blend of strategic investment, organic growth and demand.
Characterising Nanoparticle Formulations: The Analytical Toolkit
For well over 3 decades, ATA Scientific have been supplying analytical instruments to a plethora of industries and applications. Nanoparticles have loomed large for most of this time. The measurement technique employed can be as varied as the application. ‘Dynamic Light Scattering (DLS) referred to as Quasi Elastic Light Scattering (QELS), is a non-invasive, well-established technique for measuring the size and size distribution of molecules and particles typically in the submicron region, and with the latest technology, lower than 1nm. [40] Based on Brownian motion, this method goes back around 60 odd years ago. This technology is based on work at the Royal Signals and Radar facility in the UK during the 1960’s [41] from which the Malvern Correlator emerged, first Malvern Correlator used at Oxford University where they were estimating the dimension of molecules by measuring their diffusion coefficient. Fast forward to the early 1990’s we were servicing a beautiful Malvern 4800 spectrometer with goniometer and Photon Multiplier Tube, in the bowels of Chemistry at the University of Sydney where they were measuring molecular weights. At the same time the technology had advanced greatly and the first Zetasizers had been available for many years. They changed many things; Photon Correlation spectroscopy then morphed into Dynamic Light Scattering (DLS) integrating Size and Zeta Potential measurement into one system. It is ideal for LNP characterisation of size and PDI. For the fundamentals, see our explainer on Brownian motion.
In a traditional dynamic light scattering (DLS) measurement, a dispersion of particles is illuminated by a coherent light source. A fraction of the light is scattered by particles within the sample. Some of this scattering is detected at a single specified angle. The fluctuations of the scattering intensity are then analysed using a technique called autocorrelation. The size of the particles in dispersion is then derived from this autocorrelation data. This calculation uses the scattering detection angle in addition to the temperature and viscosity of the dispersant. [40]
Malvern developed a quantum leap in bringing this technology from largely academic use to industrial uniquity, the face of DLS changed forever with the Zetasizer Nano range, robust, repeatable, and the ease of use were all part of its appeal. Nano introduced NIBS, a trademark acronym for Non-Invasive Back-Scatter, this enabled the system to handle higher concentrations. The pathlength the light has to travel through the sample is reduced, this reduces multiple scattering and adsorption, hence higher concentrations can be measured, reducing the effect of dust contamination, as large particles scatter light mainly in a forward direction.
The intensity of light scattered by the sample depends upon the size and refractive index of the particles, and the angle at which scattering is detected, this is described by Mie theory. This means that particles of different sizes in the same sample are not all detected with the same sensitivity. A traditional single-angle DLS measurement may therefore report a different particle size distribution for a mixture, depending on the angle at which the measurement is performed. This explains why it is important to quote the scattering angle used to obtain a DLS result. [40]
In a MADLS measurement, the correlation data from several detection angles are combined with this knowledge of Mie theory to generate a higher resolution particle size distribution. Fitting across multiple representations of the same sample also suppresses noise in the measurement, meaning a more reliable distribution can be calculated, which undergoes less smoothing and can be calculated to a higher precision than in traditional distribution analysis techniques. These improvements mean that the Malvern Panalytical Zetasizer Ultra Red with MADLS allows improved resolution of near size components (from 3:1 to 2:1). [40] See our multi-angle dynamic light scattering measurement principle page.
The charge of the nanoparticle is also of importance and can often be a fundamental CQA. Zeta potential (or Electrokinetic potential) is a measure of the magnitude of the electrostatic repulsion/attraction between particles and is one of the fundamental parameters known to affect stability of dispersed systems. Its measurement brings detailed insight into the causes of dispersion, aggregation or flocculation, and can be applied to improve the formulation of dispersions, emulsions and suspensions. When we measure zeta potential, we are measuring the electrical potential at the slipping plane of a particulate system. A charged particle will attract counter-ions which become more diffuse the further from the particle surface. Those counter-ions that travel with the particle define the slipping plane and its associated zeta potential. Zeta potential is not a property of the particle but of the system, that is the particle and the medium it is dispersed in. Changes to the medium, such as concentration of ions, types of ions and pH will all affect the zeta potential. [42] Given the depth of history it is clear Malvern Panalytical® supplies the Zetasizer, they are used from pillar to post in every corner of the planet.
Some Nanoparticle applications are better suited to alternate technologies such as Nanoparticle Tracking Analysis (NTA). The core science under the hood of an NTA is a microscope, a great flow cell design, and advanced tracking algorithms. Immediately you will consider that the lower size limit depends on the lens and detection, this is in fact key to defining the lower size limit. Depending on the application, this can be as low as 10 to 20 nm, this does vary though. If you have a solid understanding of microscopy, it will obviate the need to explain you need to have a very dilute sample to analyse.
Particles in liquid suspension are loaded into a sample chamber, which is illuminated by a specially shaped laser beam. Particles in the path of the beam scatter the laser light which is easily collected by the 20x microscope objective and is viewed with a digital camera. The camera captures a video of the particles moving under Brownian motion.
The Nanoparticle Tracking Analysis (NTA) software analyses many particles individually and simultaneously (particle-by-particle), and by using the Stokes-Einstein equation, calculates their hydrodynamic diameters. NanoSight instruments provide high resolution nanoparticle size, count-based concentration and aggregation measurements while a fluorescence mode provides specific results for suitably labelled particles. With real time monitoring, subtle changes in the characteristics of particle populations are provided with all of these analyses confirmed by visual validation. [43] See our nanoparticle tracking measurement principle page, and our comparison of how NTA compares to DLS for measuring particle size.
Orthogonal measurements are important in scientific analysis.
Lesser-known solutions
I have discussed the apparent importance of low shear, low pressure, gentle production with little reference to the direct impact of such things on the payload. Sure, nanoparticles can encapsulate RNA and a litany of papers abound citing just how fantastical any given technology can encapsulate RNA, but at what cost to the RNA itself? Have you ever paused for thought on what is happening to the RNA in an LNP? Indeed, on a small scale, things might look ok but impose the stressors on larger scale and it may be another story.
RedShiftBio based in Boston, USA, created a technology call MMS (Microfluidic Modulation Spectroscopy), left to me to describe, I might refer to it as an FTIR on steroids! In fact, the technology utilises a Quantom cascade laser as the source with a very cool flow cell and detector to deliver high-sensitivity, label-free spectroscopy for biomolecule structure and stability. MMS enables direct measurement of secondary structure across a broad concentration range and buffer conditions, ideal for protein, RNA, and peptide characterisation. See our microfluidic modulation spectroscopy measurement principle page and our article on advancing food science with MMS.
Researchers and drug developers can rely on MMS for:
- Characterising RNA folding and stability under thermal stress
- Comparing RNA sequences or batches for structural consistency
- Detecting structural effects of encapsulation or sequence modification
- Monitoring ligand-induced structural changes in riboswitches or other regulatory elements
Interestingly, it may not only be known stressors, what about the lipid construct?
A paper on the Acuitas Tx website shows some research into ionisable lipids and their effects on RNA: ‘Ionizable lipid impurities drive RNA-lipid adduct formation in LNP, impacting in vivo expression [44]‘. Direct impurity detection in raw lipids or LNP by UPLC with MS detection was utilised. Microfluidic Modulation Spectroscopy (MMS) offers a direct, label-free approach to monitor RNA chemical and structural integrity under formulation conditions. Redshift Bio found a similar effect as Acuitas Tx, though using a different lipid, SM102. ‘Across both UV-Vis and MMS analyses, our data show clear spectral changes in polyA and polyC RNA consistent with several possible degradation mechanisms. Taken together, these findings are consistent with a model in which SM-102-derived aldehydes may adduct to nucleobase nitrogen atoms and/or possible abasic-site formation, but the relative contributions of each pathway remain unresolved by MMS-based IR measurements alone. To definitively assign covalent structures and quantify base loss, orthogonal techniques will be needed. However, this study has demonstrated the ability of MMS as a quick, first-pass assay to assess degradation in RNA samples that provides the user a direction to follow up on with additional characterization techniques. [45]‘
ATA Scientific supports Australian pharmaceutical researchers and contract manufacturers with analytical instrumentation and application expertise at every stage of nanoparticle formulation development, from early characterisation through to manufacturing quality control. Our team can advise on appropriate characterisation workflows for LNPs, liposomes, and polymer nanoparticles, and assist with instrument selection and method development.
For those interested in exploring nanoparticle characterisation or formulation systems with these instruments,
enquire today or request a demonstration.