All insights

The Ritonavir Polymorph Crisis: What It Taught Us About Crystallisation Control

23 October 2026

In pharmaceutical manufacturing, how a drug crystallises can be just as important as its chemical composition. Crystal form directly influences solubility, bioavailability, stability, manufacturability and ultimately therapeutic performance.

Few examples illustrate this better than the Ritonavir polymorph crisis. More than 25 years later, it remains one of the most significant case studies in pharmaceutical development, fundamentally changing how the industry approaches crystallisation, polymorph screening and process control.

While polymorphism can never be completely eliminated, modern continuous crystallisation technologies such as Micropore’s Advanced Crossflow (AXF™) platform provide unprecedented control over nucleation and crystal growth, helping pharmaceutical scientists reduce manufacturing risk and improve process reproducibility.

What happened when a successful drug suddenly failed?

Ritonavir failed in 1998 because a previously unknown, more stable crystal form appeared in production and could not be reversed. In 1996, Abbott Laboratories launched Ritonavir (Norvir®), a breakthrough HIV protease inhibitor manufactured as Crystal Form I. Following extensive development, regulatory approval and successful commercial production, the drug was being used by thousands of patients worldwide.

Then, in 1998, manufacturing changed unexpectedly.

A previously unknown crystal form, known as Form II, began appearing during production. Although chemically identical to Form I, the new polymorph was thermodynamically more stable and approximately 50% less soluble [1]. This reduction in solubility dramatically lowered bioavailability and could not enter the bloodstream to fight the virus, rendering the original capsule formulation ineffective.

The situation became even more problematic because Form II acted as a powerful seed crystal. Once present, microscopic crystals spread throughout manufacturing equipment and facilities, making continued production of Form I virtually impossible [1], [2].

When US scientists visited an Abbott Laboratories Italian production facility to investigate why the drug’s crystal structure was unexpectedly changing, the new, unusable crystal form “infected” their processes as well, rendering the drug ineffective globally. It appeared that microscopic dust of the new, highly stable Form II was unintentionally transferred on clothing or equipment, acting as “seeds” that triggered the rapid crystal transformation across Abbott’s production facilities.

Abbott withdrew the capsule formulation, temporarily supplied an oral solution while a new formulation was developed, and invested hundreds of millions of dollars to restore commercial production.

The incident demonstrated that crystal form is not merely a physical characteristic of an active pharmaceutical ingredient (API); it is a critical quality attribute capable of determining whether a medicine succeeds or fails.

As Abbott scientist Dr Eugene Sun famously remarked:

“We know that polymorphism will probably happen. But not why or when” [2].

More than two decades later, that statement still captures one of pharmaceutical science’s greatest challenges.

Why does polymorphism matter in drug development?

Polymorphism matters because two crystal forms of the same molecule can behave as different medicines. Many APIs can crystallise into multiple solid forms known as polymorphs. Although these polymorphs share the same chemical composition, differences in crystal packing and molecular arrangement can significantly alter:

  • Solubility
  • Dissolution rate
  • Bioavailability
  • Stability
  • Manufacturability
  • Shelf life

For today’s increasingly complex and poorly soluble drug molecules, selecting and consistently manufacturing the correct polymorph is often essential to achieving the desired therapeutic outcome.

The Ritonavir case also transformed regulatory expectations. Comprehensive polymorph screening and a detailed understanding of crystallisation behaviour are now considered essential parts of pharmaceutical development to minimise the risk of unexpected solid-state transformations after commercialisation [7].

How do you test for polymorphs?

Polymorphs are identified by combining structural, thermal and microscopic methods, because no single technique resolves every form. To detect and monitor drug polymorphs, pharmaceutical scientists rely on a range of analytical testing methods that measure differences in crystal structures, thermal behaviour and molecular spectroscopy.

Solid-State Structural Analysis

X-Ray Diffraction (XRD): The gold standard method that measures how X-rays deflect off a powder sample. Each polymorph produces a unique fingerprint pattern of peaks based on its internal atomic spacing. Malvern Panalytical®’s Aeris XRD system can help detect even the slightest changes that could pose a risk to a drug substance’s performance.

Thermal Analysis

Differential Scanning Calorimetry (DSC): Measures how a sample absorbs or releases heat as it is warmed. It detects polymorph transitions, melting points, and desolvation events by tracking changes in heat flow. MicroCal PEAQ-DSC microcalorimeters characterise the thermal stability of proteins and other biomolecules for biopharmaceutical development and manufacture. MicroCal PEAQ-DSC systems are simple to use, requiring little assay development, and no labelling or immobilisation. For a fuller explanation of the technique, see our
calorimetry measurement principle page and our guide to differential scanning calorimetry processes and technology.

Microscopic Methods

Morphologically-Directed Raman Spectroscopy (MDRS): MDRS combines static image analysis (measuring particle size and shape) with localised Raman spectroscopy (for chemical identification). It records the image of individual particles and then shoots a Raman spectrum at the centre to confirm its polymorphic identity. It is highly suited for detecting low-level polymorphic contamination in Metered-Dose Inhaler (MDI) suspensions, allowing for at least an order of magnitude increase in detection sensitivity compared to traditional vibrational spectroscopy. MDRS is delivered on the Morphologi 4-ID; see also the microscopy, image analysis and Raman spectroscopy measurement principle. View data on discriminating specific drug polymorphs via the Malvern Panalytical Acetaminophen Application Note [4].

Scanning Electron Microscopy (SEM): Provides high-resolution, 3D-like images of crystal surfaces. It maps particle morphology, texture, and crystal growth patterns. Systems like the Thermo Scientific Phenom Desktop SEM provide rapid, built-in navigation cameras and optical-to-SEM switching that make it easy to transition from broad-area screening to high-magnification morphology. Related reading: SEM applications and the role of particle morphology in the pharmaceutical industry.

Why is polymorphism so difficult to control?

Polymorphism is hard to control because the crystal that forms first is set by kinetics, not only by which form is most stable. One of the greatest challenges in pharmaceutical development is that polymorph formation is governed by both thermodynamics and kinetics.

The battle between polymorphs is a delicate balance. The first crystals to form are not necessarily the most thermodynamically stable. Instead, the polymorph that nucleates most rapidly under prevailing process conditions often appears first, even if it is only metastable. Over time, however, that metastable form may transform into a lower-energy, more stable crystal structure [2].

The rate of nucleation is controlled by the surface energy of emerging molecular clusters, making the process extraordinarily sensitive to local conditions. Small changes in solvent composition, supersaturation, temperature, reaction time, mixing efficiency, impurities or raw material sources can alter nucleation kinetics sufficiently to favour a completely different crystal form.

In the case of Ritonavir, no single cause was ever conclusively identified. One theory suggests that subtle changes in synthesis methods, solvent systems, impurities or raw material suppliers may have slowed the nucleation of Form I, allowing the more stable Form II polymorph to emerge [1].

However, Dr Sun has also suggested that the event may simply have been stochastic. The formation of Form II could have resulted from an exceptionally rare molecular event occurring after billions or even trillions of molecular interactions. Once the lower-energy polymorph appeared, it continuously shed microscopic seed crystals that propagated throughout manufacturing facilities. From that point onwards, recovering the original metastable Form I became virtually impossible.

This unpredictability explains why polymorphism remains one of the most challenging problems in pharmaceutical manufacturing.

Even today, advances in computational chemistry can accurately predict many potential crystal structures. However, predicting which polymorph will nucleate first remains extremely difficult because crystallisation kinetics are far more complex than thermodynamic stability alone.

As researchers continue developing computational tools based on surface-energy calculations and density functional theory, the industry’s ability to predict nucleation behaviour is improving. Nevertheless, controlling the crystallisation environment remains one of the most effective strategies available for managing polymorphic risk.

Polymorph Challenges Extend Beyond Pharmaceuticals

Although the Ritonavir case is the most widely cited example, disappearing polymorphs are not unique to pharmaceuticals [2], [3].

Dr Sun notes that similar challenges occur in inorganic battery materials. Lithium iron phosphate (LiFePO₄), widely used in electric vehicle (EV) batteries and grid-scale energy storage, exists in both alpha and beta phases. The alpha phase provides the crystal structure required for efficient lithium-ion transport and long-term battery performance [3].

However, variations in synthesis conditions such as acid concentration, reaction temperature or reaction time can unexpectedly produce the beta phase, which exhibits significantly poorer electrochemical performance [3].

These examples highlight a broader reality: wherever crystal structure influences product performance, controlling nucleation and crystallisation becomes critically important. Readers working in energy storage may also find our guide to structure and composition in battery manufacturing useful.

Why Crystallisation Technology Matters

The Ritonavir crisis highlighted another important lesson: the crystallisation process itself can influence which crystal form develops.

Traditional batch crystallisation relies on adding solvent or antisolvent directly into stirred vessels. Even with efficient agitation, temporary regions of high local supersaturation inevitably develop before complete mixing occurs.

These concentration hotspots create multiple competing nucleation environments throughout the reactor, increasing variability in crystal size, morphology and, under certain conditions, polymorphic outcome.

As manufacturing scales from laboratory experiments to production reactors, maintaining identical mixing conditions becomes increasingly difficult. A crystallisation process that performs consistently in a laboratory flask may behave very differently in a reactor thousands of times larger because fluid dynamics, mass transfer and mixing efficiency all change with scale.

A Better Approach to Crystallisation Control

Micropore’s Advanced Crossflow (AXF™) technology was developed specifically to address these challenges [5].

Rather than relying on turbulent mixing within a stirred vessel, AXF introduces one liquid phase through laser-engineered porous stainless-steel membranes into a continuously flowing second phase. Each membrane pore acts as a precisely controlled micro-mixing point, creating highly uniform solvent exchange and supersaturation throughout the crystallisation process.

This controlled environment provides significantly tighter control over nucleation kinetics, the very mechanism that determines how molecules first assemble into crystals.

By eliminating local supersaturation hotspots and generating highly reproducible mixing conditions, AXF helps reduce process variability while enabling more consistent particle size distributions, crystal morphology and crystallisation behaviour.

Uniform Supersaturation

By preventing the concentration gradients common in stirred reactors, AXF creates a highly uniform crystallisation environment that reduces random nucleation events and promotes more consistent crystal formation.

Precise Nucleation Control

AXF promotes nucleation-controlled crystallisation, generating large numbers of uniformly sized crystals with narrower particle size distributions and improved morphology control. In many applications this can reduce or eliminate the need for crystal seeding.

Controlled Crystallinity

The technology enables researchers to tailor crystallinity itself. Depending on processing conditions, APIs can be produced as highly crystalline materials or as amorphous solids, providing formulation scientists with greater flexibility when working with poorly soluble compounds.

Low-Shear Continuous Processing

Rapid yet gentle solvent exchange occurs under low-shear conditions, minimising crystal breakage while maintaining highly reproducible processing conditions during continuous operation.

Predictable Scale-Up

One of AXF’s most significant advantages is scale-up.

Conventional crystallisation processes often behave differently as reactor size increases because mixing conditions change dramatically. AXF maintains the same mixing mechanism from laboratory development through commercial manufacture. Scale-up is achieved through increased throughput or parallelisation of membrane channels rather than changes to the crystallisation environment itself.

This significantly improves confidence that particle size, morphology and process performance developed in the laboratory can be reproduced at manufacturing scale. The same principle underpins the
Micropore AXF Pathfinder at development scale and the Horizon series at GMP scale.

What Could This Have Meant for Ritonavir?

It is important to be scientifically accurate: no crystallisation technology can guarantee that an unexpected polymorph will never appear.

Polymorphism is governed by the inherent thermodynamics and kinetics of each individual molecule.

However, technologies such as Micropore AXF are specifically designed to improve control over the process variables that influence crystal formation.

Had this level of process control been available during Ritonavir development, it may have offered several important advantages:

  • More reproducible polymorph screening during development.
  • Better control of supersaturation and nucleation conditions.
  • Earlier identification of competing crystal forms.
  • More consistent production of the desired polymorph.
  • Greater confidence when transferring processes from laboratory to manufacturing scale.

Importantly, AXF operating parameters can also be optimised to favour different crystal forms by carefully controlling solvent exchange, supersaturation and nucleation kinetics. While this cannot eliminate polymorphism, it provides scientists with significantly greater control over crystallisation behaviour than conventional batch processing and lowers the risk.

The Future of Pharmaceutical Crystallisation

The Ritonavir crisis transformed pharmaceutical development forever. It demonstrated that understanding crystallisation is just as important as understanding chemistry.

Today, pharmaceutical companies invest heavily in polymorph screening, crystallisation science and process analytical technologies because crystal form directly impacts product quality, regulatory compliance and commercial success.

Continuous membrane crystallisation platforms such as Micropore AXF™ represent the next evolution in pharmaceutical manufacturing. By delivering precise control over supersaturation, solvent exchange, nucleation, particle size, crystallinity and crystal morphology, AXF enables more robust, reproducible and scalable crystallisation processes from early discovery through commercial manufacture.

As APIs become increasingly complex and formulation challenges continue to grow, the lessons from Ritonavir remain highly relevant. While unexpected polymorphs may never be completely eliminated, greater control over crystallisation significantly reduces manufacturing risk, accelerates process development and improves manufacturing robustness.

For pharmaceutical scientists, the question is no longer whether crystallisation matters, it is how much control they have over it.

Telmisartan AXF-1 study

A recent study published in Crystal Growth & Design demonstrated the advantages of Micropore Technologies’ Advanced Crossflow (AXF™) system for continuous antisolvent crystallisation of the poorly soluble API telmisartan [6]. By introducing the API solution through laser-engineered stainless-steel membranes into a flowing antisolvent, the AXF system provided highly controlled micromixing, enabling precise control over supersaturation, nucleation, and crystal growth. Unlike conventional batch mixing, which produced inconsistent mixtures of crystalline and amorphous material, the AXF platform delivered a far more reproducible crystallisation environment and allowed researchers to tailor the solid-state form by adjusting solvent composition and process conditions. The study also demonstrated that the continuous crossflow process can consistently produce sub-micron particles with controlled crystal morphology, highlighting AXF’s potential to improve API solubility, reproducibility, and scalability from early formulation development through to commercial pharmaceutical manufacturing.

The key message is AXF does not just make nanoparticles, AXF controls the fundamental physics of particle formation, giving researchers control over size, morphology, reproducibility and scale-up.

Learn more about Micropore AXF™ technology

ATA Scientific is the Australian and New Zealand distributor for Micropore Technologies. To discuss how Advanced Crossflow crystallisation can support your pharmaceutical or nanoparticle formulation workflow,
enquire today or request a demonstration.

Frequently Asked Questions

How does a polymorph change affect a drug's performance?

A polymorph change alters the physical properties of the solid without changing its chemistry, so solubility, dissolution rate and bioavailability can all shift. In the Ritonavir case, Form II was roughly 50% less soluble than Form I, which was enough to render the approved capsule formulation ineffective.

Which analytical techniques detect polymorphs?

X-ray diffraction provides the definitive structural fingerprint, differential scanning calorimetry detects thermal transitions between forms, and morphologically-directed Raman spectroscopy identifies low-level polymorphic contamination in formulated products. Scanning electron microscopy adds high-resolution morphology. Most polymorph screening programmes combine several of these.

Can polymorphism be eliminated entirely?

No. Polymorphism is governed by the thermodynamics and kinetics of each individual molecule, so no process technology can guarantee an unexpected form will never appear. What process control can do is reduce the variability in the conditions that drive nucleation.

How does continuous crossflow crystallisation reduce polymorphic risk?

Continuous crossflow crystallisation replaces turbulent mixing in a stirred vessel with uniform solvent exchange through a laser-engineered membrane. This removes the local supersaturation hotspots that create competing nucleation environments, giving more reproducible control of the conditions under which crystals first form.

Does a crystallisation process behave the same way at manufacturing scale?

Not necessarily. In conventional batch crystallisation, fluid dynamics, mass transfer and mixing efficiency all change as reactor size increases, so a process validated in the laboratory can behave differently in production. Membrane crossflow platforms scale by increasing throughput or parallelising channels rather than by changing the mixing mechanism.

References

[1] J. Bauer, S. Spanton, R. Henry, J. Quick, W. Dziki, W. Porter and J. Morris, “Ritonavir: An Extraordinary Example of Conformational Polymorphism,” Pharmaceutical Research, vol. 18, no. 6, pp. 859-866, 2001. [Online]. Available: https://doi.org/10.1023/A:1011052932607. [Accessed 31 August 2026].

[2] J. D. Dunitz and J. Bernstein, “Disappearing Polymorphs,” Accounts of Chemical Research, vol. 28, no. 4, pp. 193-200, 1995. [Online]. Available: https://doi.org/10.1021/ar00052a005. [Accessed 31 August 2026].

[3] Chemistry World, “The Curious Case of Disappearing Polymorphs,” Royal Society of Chemistry. [Online]. Available: https://www.chemistryworld.com/features/the-curious-case-of-disappearing-polymorphs/4023257.article. [Accessed 31 August 2026].

[4] Malvern Panalytical, “Polymorph Characterisation Using Morphologically Directed Raman Spectroscopy (MDRS),” Application Note AN240415. [Online]. Available: https://www.malvernpanalytical.com/en/learn/knowledge-center/application-notes/an240415-polymorphs-mdrs. [Accessed 31 August 2026].

[5] Micropore Technologies, “Advanced Crossflow (AXF™) Technology: Precision Particle Engineering and Scalable Formulation Processing,” Micropore Technologies Technical Resources. [Online]. Available: https://microporetech.com/applications/other-drug-formulation-techniques/crystallisation/. [Accessed 31 August 2026].

[6] M. J. Bennett, E. Beveniou, A. R. Kerr and M. M. Dragosavac, “Antisolvent Crystallization of Telmisartan Using Stainless-Steel Micromixing Membrane Contactors,” Crystal Growth & Design, vol. 23, no. 5, pp. 3720-3730, 2023. [Online]. Available: https://doi.org/10.1021/acs.cgd.3c00123. [Accessed 31 August 2026].

[7] S. L. Morissette, S. Soukasene, D. Levinson, M. J. Cima and O. Almarsson, “Elucidation of crystal form diversity of the HIV protease inhibitor ritonavir by high-throughput crystallization,” Proceedings of the National Academy of Sciences USA, vol. 100, no. 5, pp. 2180-2184, 2003. [Online]. Available: https://doi.org/10.1073/pnas.0437744100. [Accessed 31 August 2026].

Further viewing (not cited as a source): Veritasium, “The crystal that could destroy all medicine.” Available: https://youtu.be/ksn5yrsC3Wg

Expand