This guide is designed to help you navigate the options for particle measurement, compare analytical methods, and make informed choices for your laboratory.
Why does particle analysis matter?
Particle analysis matters because size, shape, charge and surface structure determine how a material behaves in a formulation, a process and a finished product. Selecting the right particle characterisation system can be challenging. With numerous analytical techniques available, each offering different measurement principles, particle size ranges, and capabilities, choosing the best solution requires careful consideration of your samples, applications, and research objectives. Reliable particle characterisation enables scientists to:
- Understand particle behaviour in suspensions, powders, or emulsions.
- Predict interactions with surfaces and other materials.
- Meet regulatory and compliance requirements and ensure product consistency and quality.
- Reduce development time by selecting appropriate formulations or processing methods.
This comprehensive buyer’s guide simplifies the decision-making process by comparing the most widely used particle characterisation technologies, including Dynamic Light Scattering (DLS), Nanoparticle Tracking Analysis (NTA), Laser Diffraction, Automated Imaging, Scanning Electron Microscopy (SEM), Surface Area & Porosity Analysis, Powder Rheology, and Tensiometry. Ideal for those working in pharmaceuticals, biotechnology, food, chemicals, batteries, mining, advanced materials, or academic research, this guide will help you understand which techniques are best suited to your application, the strengths and limitations of each method, and when complementary technologies can provide deeper insight.
Whether you’re purchasing your first particle analyser or expanding your laboratory capabilities, this guide will help you make an informed investment with confidence. At ATA Scientific, we are committed to providing access to the most advanced analytical technologies with ongoing support. We offer a valuable platform for knowledge exchange, training, and collaborative problem-solving. The technologies discussed in this buyer’s guide can be available for demonstration. To book, request a demonstration or enquire today.
How to Select the Right Technology for Your Lab
What do you need to measure?
Start by defining the particle property that actually drives your product or process, because that single answer narrows the technique list faster than any other question. Before selecting an instrument, it is important to define the key questions you need your analysis to answer. For example, when choosing a particle sizing technique, start by defining your goals. What do you want to achieve? Whether it’s detecting agglomerates or controlling the fine particle fraction, your objectives will guide you to the right techniques with the necessary sensitivities. A number of criteria must be considered when deciding which particle characterisation techniques you need.
Fundamental questions to ask are:
- Which particle properties are important to your sample?
- What is the particle size range you need to work over?
- Are your samples polydisperse, that is, do you need a wide dynamic range?
- How quickly do you need to be able to make measurements?
- Do you need to measure at high resolution?
- Do you need good statistical sampling for robust QC measurement?
- Do you need to disperse your sample wet or dry?
Understanding the analytical objective is the first step in choosing the right technology. Are you interested in:
Particle size distribution (PSD)?
PSD is one of the most important characteristics influencing particle behaviour, including stability, solubility, dissolution, flow properties, and overall product performance. Particle behaviour can change significantly across size ranges, with nanoparticles (<200 nm) often exhibiting very different physical and chemical properties compared with micron-sized powders. Importantly, the complete size distribution is often more informative than the average particle size alone, as small populations of larger particles or aggregates can impact stability, affect performance, and compromise product quality. Common particle sizing techniques include:
- Dynamic Light Scattering (DLS) (<1 nm to <10 µm), Zetasizer
- Nanoparticle Tracking Analysis (NTA) (10 nm to 1 µm), NanoSight Pro
- Laser Diffraction (<100 nm to >1 mm), Mastersizer 3000+, Insitec, Spraytec
- Automated Imaging (<1 µm to >1 mm), Morphologi
Particle shape and morphology?
Particle shape plays an important role in determining flowability, packing density, dissolution behaviour, and overall product performance. Irregular, elongated, or highly textured particles can significantly influence biological uptake, processing efficiency, and material handling. Shape analysis is often used alongside particle size measurements to provide a more complete understanding of particle behaviour. Common particle shape analysis techniques include:
- Automated optical microscopy, Morphologi
- Scanning Electron Microscopy (SEM), Phenom SEM
See also our particle shape and morphology applications.
Surface charge and stability (Zeta Potential)?
Zeta potential provides an indication of colloidal stability by measuring the surface charge of particles suspended in a liquid. A high positive or negative zeta potential generally suggests greater electrostatic repulsion and improved stability, while low zeta potential values may indicate an increased risk of particle aggregation. It is a critical measurement for formulations in food, biotechnology, pharmaceuticals, and nanomedicine where maintaining dispersion stability is essential. Common surface charge and stability analysis techniques include:
See also our surface charge and stability applications.
Chemical composition or particle identification?
Chemical composition helps to distinguish different particle types, detect contaminants, and confirm formulation components. This information is essential when particle size and shape alone are not sufficient to understand performance, particularly in complex mixtures, pharmaceuticals, advanced materials, and industrial processes. Common chemical composition analysis techniques include:
- Automated optical microscopy, Morphologi ID (Raman Spectroscopy)
- Scanning Electron Microscopy (SEM), Phenom SEM (with X-ray/EDS)
See also particle imaging and chemical ID.
Particle concentration?
Particle concentration provides important information about particle abundance, loading, and consistency. Unlike size measurements alone, concentration data helps quantify changes in formulation quality, detect particle loss or aggregation, and assess dose, stability, and performance in applications such as nanomedicine, extracellular vesicles, drug delivery, and advanced materials. Common particle concentration analysis techniques include:
- Dynamic Light Scattering (DLS), Zetasizer
- Nanoparticle Tracking Analysis (NTA), NanoSight Pro
Researchers working with extracellular vesicles may also want our exosome isolation and characterisation page.
Surface Area & Porosity?
Surface area and porosity measurements provide insight into the available surface structure of a material, influencing adsorption capacity, dissolution behaviour, and catalytic activity. These properties are particularly critical for energy storage materials, catalysts, adsorbents, and advanced powdered materials, where pore size and surface accessibility directly impact performance and efficiency. Common surface area and porosity analysis techniques include:
- BET surface area analysis, TriStar
- Gas adsorption, 3Flex, Chemisorb, AutoChem,
ASAP 2020 Plus, Gemini, AccuSorp - Mercury porosimetry, AutoPore
Powder Flow and Rheology?
Powder flow and rheology measurements reveal how powders behave during processing, handling, and storage by assessing properties such as flowability, cohesion, and compressibility. The FT4 Powder Rheometer provides
dynamic, shear, and bulk flow measurements that provide deeper insight into powder behaviour beyond what particle size alone can predict, helping to optimise formulation, manufacturing processes, and product consistency.
Surface Tension?
Surface tension measurements provide insight into the interfacial energy between liquids or between a liquid and gas, helping to understand how materials interact at their boundaries. These measurements are essential for predicting wetting behaviour, particle dispersion, and formulation stability, particularly in emulsions, suspensions, foams, coatings, and other liquid-based systems where interfacial properties influence performance. Common surface tension analysis techniques include:
- Contact angle measurement, KRUSS DSA, Tensiio, MSA
- Drop shape analysis, KRUSS DSA
- Dynamic surface tension measurement, KRUSS DSA, BPT, SDT
See also our surface and interfacial tension applications and our explainer on how tensiometers work.
Which technique suits your sample type?
The physical form of the sample, wet dispersion, dry powder, aerosol or porous solid, rules out more techniques than any other single factor. Whether your sample is a wet dispersion, dry powder, aerosol, or spray will influence which analytical methods are suitable, as each technology is designed to measure particles under specific conditions and across different size ranges.
For nanometre-scale particles (<1 µm) suspended in liquids, techniques such as Dynamic Light Scattering (DLS) and Nanoparticle Tracking Analysis (NTA) are commonly used. These methods are particularly suited to nanoparticles, proteins, lipid nanoparticles (LNPs), polymer dispersions, drug delivery systems, and extracellular vesicles, where accurate measurement of particle size, distribution, morphology, and concentration is critical. DLS can also measure zeta potential, providing valuable insight into colloidal stability, while NTA complements DLS by measuring individual particle size and concentration in heterogeneous samples. For a direct comparison of the two, see how NTA compares to DLS for measuring particle size.
For micron- to millimetre-sized particles, particularly in dry powders, granules, and bulk materials, laser diffraction and automated imaging are widely used. Laser diffraction provides rapid, reproducible particle size distributions across a broad size range, making it ideal for routine quality control and research. Automated imaging (Optical and Scanning Electron Microscopy/SEM) adds particle shape and morphological information, making it particularly useful for pharmaceutical powders, food ingredients, minerals, battery materials, pigments, and additive manufacturing powders where particle characteristics influence flowability, packing, dissolution, and overall product performance. See also 5 reasons to combine laser diffraction particle sizing and image analysis.
For sprays, aerosols, and atomised droplets, specialised laser diffraction systems can measure particle or droplet size directly within the spray plume. These real-time measurements help optimise atomisation processes used in pharmaceutical inhalers, agricultural sprays, spray drying, combustion research, and industrial manufacturing. See our aerosol and droplet sizing applications.
When analysing porous materials, particle size alone is often insufficient. Techniques such as BET surface area analysis, gas adsorption, and mercury porosimetry measure surface area, pore volume, and pore size distribution, providing critical information about adsorption capacity, dissolution behaviour, and catalytic activity. These measurements are widely used to characterise catalysts, battery materials, adsorbents, ceramics, and other advanced porous materials.
See our surface area, porosity and density applications. In many applications, no single technique provides a complete understanding of particle behaviour. While one method may accurately measure particle size, another may reveal particle shape, surface charge, chemical composition, concentration, or porosity. Combining complementary techniques enables researchers to better understand how particles behave, interact, and perform in real-world applications. This multi-technique approach improves confidence in analytical results, helps identify formulation or processing issues, and supports more informed decisions throughout research, development, manufacturing, and quality control.
By first defining which of these properties are most important, you can narrow down which technology best fits your needs.
Decision-Making Framework
Choosing the right particle characterisation technology doesn’t have to be complicated. By thinking about your needs step by step, you can quickly narrow down the best options for your lab. Use this framework to narrow down the most suitable analytical approach.
| Step | Key question | Consideration | Recommended technologies |
|---|---|---|---|
| 1 | What do you need to measure? | Particle size | Laser Diffraction, DLS, NTA |
| Particle shape & morphology | Automated Imaging, SEM | ||
| Surface charge | Zeta Potential (ELS) | ||
| Particle concentration | NTA | ||
| Chemical composition | Raman Imaging, SEM-EDS | ||
| Surface area & porosity | BET, Gas Adsorption, Mercury Porosimetry | ||
| Powder behaviour | Powder Rheometry | ||
| Surface/interfacial properties | Tensiometry | ||
| 2 | What is your sample type? | Nanoparticles, proteins, colloids | DLS, NTA |
| Suspensions, emulsions | Laser diffraction, DLS | ||
| Dry powders, granules | Laser Diffraction, Imaging, SEM | ||
| Sprays, aerosols | Laser Diffraction | ||
| Porous materials, catalysts | BET, Gas Adsorption, Porosimetry | ||
| 3 | What particle range do you need to measure? | <1 µm | DLS, NTA |
| 10 to 1000 nm | NTA | ||
| 0.01 to 3500 µm | Laser Diffraction | ||
| 1 µm to mm scale | Automated Imaging | ||
| High resolution imaging | SEM | ||
| 4 | Is particle size enough? | Yes | Select the most appropriate sizing technique based on steps 2 and 3 |
| No | Add complementary techniques to measure shape, chemistry, concentration, surface properties or powder flow behaviour | ||
| 5 | How will the instrument be used? | R&D | Orthogonal techniques for deeper understanding |
| QC | Automated, fast, high throughput systems with autosampling options | ||
| Regulated environment | Systems with validated methods and compliance | ||
| 6 | Final selection | Single or multiple parameters | Combine complementary techniques for a complete sample profile |
Overview of Key Particle Characterisation Technologies
Here we explore the most widely used particle characterisation methods, highlighting their advantages, limitations, and typical applications.
| Technology | What it measures | Range | Strengths and limits | Applications |
|---|---|---|---|---|
| Dynamic Light Scattering (DLS), e.g. Zetasizer Advanced series | Particle size (hydrodynamic diameter) in liquids. Surface charge (zeta potential) of particles in suspension to predict stability. | ~0.3 nm to 10 µm [3] | Fast, simple, non-destructive, requires small sample volume, autosampler option. Assumes spherical particles, sensitive to contaminants. | Proteins, liposomes, nanoparticles, polymer suspensions, emulsions, drug delivery systems. |
| Nanoparticle Tracking Analysis (NTA), e.g. NanoSight Pro | Nanoparticle size and concentration plus detection of fluorescently labelled subpopulations, identifying biomarkers, cargo, and nanoparticles in complex matrices. | ~10 nm to 1000 nm [4] | Measures particles individually, providing number-based size and concentration data, and visualises particles in real time. Sample dilution often required. | Nano-drug delivery systems, extracellular vesicles (EVs), exosomes, viruses. |
| Laser Diffraction (LD), e.g. Mastersizer 3000+ series | Particle size distribution in wet and dry samples | ~0.01 µm to 3500 µm [5] | Rapid analysis, reproducible, wide range of samples and sizes, real-time monitoring (PAT) applications, autosampler option. Assumes spherical particles for calculation. | Powders, emulsions, suspensions and sprays used in pharma, paints, food, building, minerals, mining and polymers. |
| Optical Microscopy, automated, e.g. Morphologi 4-ID | Size, shape, and other morphological parameters of individual particles. Raman spectrometer option for chemical ID. | ~1 µm to several mm [6] | Provides detailed shape information (aspect ratio, roundness) and particle classification or ID. Longer measurement times. | Irregularly shaped particles, fibres, aggregates found in pharma, food and mineral samples. |
| Scanning Electron Microscope (SEM), e.g. Phenom XL SEM | High resolution imaging of particle size and morphology. EDS (X-ray) detection for elemental composition. | Sub-nanometer to micrometer scale [7] | Fast and easy to use, provides high resolution imaging with elemental analysis of large samples up to 100 mm x 100 mm. Cannot image wet samples. | Advanced materials, industrial manufacturing (paints, coatings, automotive, aerospace), forensics, electronics, environmental. |
| Gas adsorption and BET analysis, e.g. TriStar, 3Flex, Gemini |
Surface area and porosity of powders. Physisorption analysis is for understanding how much surface is available, while chemisorption reveals how that surface behaves chemically. | Physisorption (BET): total surface area and micropore/mesopore analysis. Chemisorption: active surface and chemical functionality. [8] | Provides data on micro- and mesoporous materials. Widely accepted standard method, highly reproducible and quantitative, suitable for a broad range of powdered and porous materials. Sample preparation and degassing are critical. | Catalysts and catalyst supports, battery and energy materials, adsorbents and MOFs, advanced porous materials. |
| Mercury Porosimetry, e.g. AutoPore | Intrusion of mercury into pores under pressure | Approximately 3 nm to 1000 µm, covering mesopores to macropores. [9] | Very wide pore size range. Ideal for measuring macroporosity not accessible by gas adsorption. Provides bulk density and porosity data. Destructive technique, uses mercury (requires strict safety and disposal protocols), not suitable for soft, compressible, or fragile materials. | Building materials and cements, geological samples, ceramics and refractories, battery electrodes and separator materials. |
| Powder Rheology, e.g. FT4 Powder Rheometer | Measures powder flow and dynamic behaviour under stress. Best used alongside particle size and morphology techniques. | Applicable to fine cohesive powders (<10 µm) to coarse granules (>1 mm) [10] | Predicts powder behaviour: flowability, cohesion, compressibility, spreading, packing. Less suitable for very wet or highly fibrous materials. | Powder processing, additive manufacturing, foods, coatings. |
| Tensiometry, drop shape or contact angle, e.g. DSA, SDT, BPT |
Measure surface and interfacial tension, CMC, wetting properties in liquids. | Spinning drop tensiometers offer measurement to ultralow regions, important for microemulsions and surfactant research. Bubble pressure tensiometers focus on dynamic surface tension, typically from about 10 to 100 mN/m, with high time-resolution measurements. [11] | Dynamic and static measurements, temperature control options, high precision and resolution. High-precision tensiometers with temperature control and advanced software demand higher initial investment. | Pharmaceutical formulations, cosmetics, food and beverage, coatings and inks, surfactant cleaning agents, enhanced oil recovery and petrochemicals. |
What should you consider beyond measurement capability?
Ease of use, sample preparation, throughput, regulatory fit and local service support determine whether an instrument actually gets used once it is installed. When evaluating particle characterisation systems, it is important to look beyond measurement capability alone. Ease of use should be carefully considered, particularly in multi-user laboratories where staff may need to operate the instrument independently. Sample preparation requirements can significantly affect workflow efficiency and should align with available expertise and time constraints. Throughput and automation are also critical, especially in quality control or labs where there is a high number of samples processed per day. Regulatory requirements may further influence instrument selection, particularly in pharmaceutical or biomanufacturing settings where GMP-ready software and data integrity are essential.
Finally, access to reliable local service and technical support is often overlooked but can be crucial for long-term success. Local expertise ensures faster response times, ongoing training, and confidence that the system will continue to perform as expected throughout its lifetime. See our service and maintenance and training and application support pages.
Why Work with ATA Scientific
For over 35 years, ATA Scientific has supported researchers in Australia and New Zealand, supplying instruments, training, and service for particle characterisation. Our expertise spans biotech, pharma, mining, minerals, chemical, polymer, food science, and materials research to name a few. We don’t just supply instruments, we help you select the most suitable technology, provide hands-on training, and ensure long-term reliability. Read more about who we are.
Next Steps
Particle characterisation is a vital tool for modern science. With multiple technologies available, the right choice depends on your sample type, research goals, and throughput needs. There is no single particle characterisation technique that answers every analytical question. The best solution depends on your sample type, particle size range, application goals and workflow requirements. By combining complementary technologies such as particle sizing, imaging, surface analysis, rheology and interfacial measurements, researchers can develop a complete understanding of their materials and make better decisions about formulation, processing and quality control. Need help selecting the right particle characterisation system? Enquire today for advice and application support, or request a demonstration and quote.